Building Facade Maintenance Repair And Inspection Pdf

Posted on by

Metal Buildings 1. Metal Building 1. Star Building Systems Glossary of Metal Building Terms. This is a list of commonly used terms and their definitions. This list is not intended to be all inclusive, but rather to provide enough information to familiarize the reader with metal building terminology. Click here to view PDF version. AAccessory. A building product that supplements a basic solid panel building such as a door, window, skylight,ventilator, etc. ActiveMetallurgy A metal that will corrode in the presence of moisture and a noble metal See Galvanic Action and Galvanic Series Chart in this Glossary. Agricultural Building. A structure designed and constructed to house farm implements, hay, grain, poultry, livestock or otherhorticultural products. Such structure shall not include habitable or occupiable spaces, spaces in whichagricultural products are processed, treated or packaged nor shall an agricultural building be a place ofoccupancy by the general public. AISCAmerican Institute of Steel Construction. Building Facade Maintenance Repair And Inspection Pdf ReaderBuilding Facade Maintenance Repair And Inspection PdfThe basic function of the envelope or enclosure of a building or structure is to protect the covered or otherwise conditioned interior spaces from the surrounding. The thermal assessment of window assemblies, curtain walling and nontraditional building envelopes Second edition Description. This document is intended for use. Building Facade Maintenance Repair And Inspection Pdf MergerAISEAssociation of Iron and Steel Engineers. AISIAmerican Iron and Steel Institute. Aluminum. A corrosion resistant metallic element. Aluminum alloy coated sheet is often used for metal roofing andwall panels. Aluminum Coated Steel. Steel coated with aluminum for corrosion resistance. Anchor Bolt Plan. A plan view drawing showing the diameter, location and projection of all anchor rods for the components of the Metal Building System and may show column reactions magnitude and direction. The maximumbase plate dimensions may also be shown. Anchor Bolts. See Anchor Rods. Anchor Rods. The term anchor rod is used for threaded rods embedded in concrete to anchor structural steel. The term rod is intended to clearly indicate that these are threaded rods, not structural bolts, and should bedesigned as threaded parts using the material specified in the latest edition of AISC. The embedded endof the rod may be secured in the concrete by means of a head, threading with a nut on the end, a hook orother deformation, by welding to reinforcing steel or other means. Anodic. With regard to metal and galvanic response, when two metals are connected in an electrolyte, they willform a galvanic cell, with the higher metal in the galvanic series being the anode. The anodic metal, beingmore active oxidizes first, thus protecting the cathodic metal from corrosion see cathodic. ANSIAmerican National Standards Institute. Approval Drawings. A set of drawings that may include framing plans, elevations and sections through the building for approval of the buyer. Apron Flashing. A flashing located at the juncture of the top of the sloped roof and a vertical wall or steeper sloped roof. Architectural Panel. Any panel that has a primary purpose of the aesthetic enhancement of a building or structure. ASCEAmerican Society of Civil Engineers. ASCE Rail. American Society of Civil Engineers rated steel shape similar to a train track. Placed on top of a runwaybeam, it acts as a guide for top running cranes. ASDAllowable Stress Design. ASHRAEAmerican Society of Heating, Refrigerating and Air Conditioning Engineers. Asphalt Felt. An asphalt saturated andor an asphalt coated felt. See Felt. Assembly. A group of mutually dependent and compatible components or sub assemblies of components. ASTMAmerican Society for Testing and Materials. Astragal. A closure between the two leaves of a double swing or double slide door. Automatic Crane. A crane which when activated operates through a pre set cycle or cycles. Automatic Welding. A welding procedure utilizing a machine to make a weld. Auxiliary Crane Girder. A girder arranged parallel to the main girder for supporting the platform, motor base, operators cab, control panels, etc., to reduce the torsional forces that such load would otherwise impose on the main crane girder. Auxiliary Hoist. A supplemental hoisting unit, usually designed to handle lighter loads at a higher speed than the maincrane hoist. Auxiliary Loads. Dynamic live loads such as those induced by cranes and material handling systems. Axial Force. A force tending to elongate or shorten a member. BBar Joist. A name commonly used for Open Web Steel Joists. Barrel Vault. A semi cylindrical shaped roof. Base Angle. An angle secured to a wall or foundation used to attach the bottom of the wall paneling. Base Flashing. The lower flashing component of a two component metal flashing detail. The component flashing detailsare often used either for expedience or to allow differential thermal movement between building elements or accessories. The lower component is the base flashing the upper component is the counter flashing. Base Plate. A plate attached to the bottom of a column that rests on a foundation or other support, usually secured byanchor rods. Base Tube. A continuous member imbedded in the edge of the foundation to which the wall panels are attached. Batten. A strip of wood common to non structural panels that is used to support the vertical ribs of adjacent metalpanels. Batten Cover. 1. A separate strip of metal used to cover the wood batten, and join the vertical ribs of adjacent metalpanels on either side of the batten. Download La Rush Pc. A strip of formed metal used to span the void area and join the vertical legs of adjacent metal panels. Batten Seam. 1. A metal panel profile attached to and formed around a wood or metal batten,2. A metal panel profile that imitates the traditional batten seam system but omits the wooden batten. Bay. The space between the main frames measured normal to the frame. Beam. A member, usually horizontal, that is subjected to bending loads. There are three types, simple,continuous, and cantilever. Beam and Column. A structural system consisting of a series of rafter beams supported by columns. Often used as the endframe of a building. Bearing End Frame. See Beam and ColumnSee Bearing Hot RolledBearing Frame Endwall BFEWSee Beam and ColumnSee Bearing Hot RolledBearing Hot Rolled. Also referred to as a Bearing End Frame or Bearing Frame Endwall BFEW. A Bearing Hot Rolled is astructural system consisting of a series of hot rolled rafter beams supported by hot rolled columnsconnected by a series of pinned connections. Often used as the end wall framing of a building. See Beam and ColumnBearing Plate. A steel plate that is set on the top of a masonry support on which a beam or purlin can rest. Bent. See Main Frame. Bermuda Seam. A metal panel featuring a stepped profile. The panel runs perpendicular to the slope of the roof. Bill of Materials. A list that enumerates by part number or description each piece of material or assembly to be shipped. Also called tally sheet or shipping list. Bird Screen. Wire mesh used to prevent birds from entering the building through ventilators and louvers. Blanket batt Insulation. A layer or sheet of flexible fiberglass thermal insulation. Blind Rivet. A small headed pin with expandable shank for joining light gage metal. Typically used to attach flashing,gutter, etc. BOCABuilding Officials and Code Administrators International, Inc. Box Girder. Girders, trucks or other members of rectangular cross section enclosed on four sides. Bracing. Rods, angles or cables used in the plane of the roof and walls to transfer loads, such as wind, seismicand crane thrusts to the foundation. Bracket. A structural support projecting to a structural member. Examples are canopy brackets, lean to brackets,and crane runway brackets. Brake. A machine used to bend, fold or form sheet metal. Administrative Bulletins Department of Building Inspection. San Francisco Building Code. All Files are in PDF Format. AB TITLEAB 0. 01. Preparing Administrative Bulletins. AB 0. 04. Priority Permit Processing Guidelines WordAB 0. Local Equivalency Case by Case Application Procedures WordAB 0. Accessible Restrooms Located within a Reasonable Distance. Superceded by DA 1. AB 0. 09. Local Equivalency for Approval of New Openings in New and Existing Building Property Line Walls WordAB 0. Local Equivalency for Approval of Communicating Openings Between Buildings on Separate Properties. AB 0. 11. Use of Powered Door Operators in Lieu of Exterior and Interior Door Side Clearances. Superceded by DA 0. AB 0. 12. Use of Powered Door Operators in Lieu of Level Landings at Doors. Superceded by DA 0. AB 0. 13. Application of Disabled Access Provisions to Historic Buildings. AB 0. 15. Allowable Temporary Interruptions to Disabled Access. AB 0. 17. Exception to Requirements for Disabled Access to Vacant Spaces. AB 0. 18. Local Equivalency for Approval of Emergency Escape or Rescue Windows at Courts and Lightwells. AB 0. 19. Local Equivalency for Approval of Fire Escapes as a Required Means of Egress. AB 0. 20. Local Equivalency for Exiting Through a Garage Area for Type V, Group R Buildings. AB 0. 23. Crane Site Safety Plan For the operation of tower cranes on high rise building structures. AB 0. 24. RESERVEDAB 0. Pre application Requirements for State Industrial Safety Permit for Certain Trenching, Demolition,and Construction Activities. AB 0. 26. Noise Insulation Enforcement Procedures. AB 0. 27. Illegal Unit Re occupancy Enforcement Procedures. AB 0. 28. Pre application and Pre addendum Plan Review Procedures. AB 0. 29. HELD FOR REVISION Procedure for Approval of Homeless Shelters. AB 0. 31. Identification of Revisions on Pages of Drawings. AB 0. 32. Site Permit Processing. Legacy Version. AB 0. Procedure for Assigning Street Numbers AddressesAB 0. Special Inspection for Demolition Work. AB 0. 37. Non complying Exit Separation in Existing Group B, F 1, M, S 1 and S 2 Occupancies. Legacy Version. AB 0. Referral of Design Professionals and Contractors to Regulatory Agencies. AB 0. 42. Board of Examiners Request for Variance, New Materials, or Alternate Methods of Construction. AB 0. 43. Ventilation of Public Spaces in Group R Occupancies. AB 0. 46. Special Inspection and Structural Observation Documentation Procedures WORDAB 0. Specific Submittal Criteria for Reports, Special Inspections and Final Acceptance Testing of Smoke Control Systems. AB 0. 56. Disabled Access Compliance Status Documentation. AB 0. 57. Local Equivalency for Approval of Roof Hatches in Lieu of Stairway Penthouse in Designated Buildings. AB 0. 58. Procedures for Seismic Instrumentation of New Buildings. AB 0. 60. Information Technology Rooms Defined and Requirements. AB 0. 78. Criteria for Waiving Special Inspection Requirements for Signs, Awnings and Canopies. AB 0. 82. Guidelines and Procedures for Structural Design Review. AB 0. 83. Requirements and Guidelines for the Seismic Design of New Tall Buildings using Non Prescriptive Seismic Design Procedures. AB 0. 84. Guidelines for the Structural Review of Continuous Tiedown Systems Used to Resist Overturning of Light Framed Wood Shear Walls. AB 0. 88. Collection and Storage of Trash, Recycling and Compostable Materials. AB 0. 90. Destination Based Elevator Control System Requirements. AB 0. 93 Implementation of Green Building Regulations AB 0. Definition and Design Criteria for Voluntary Seismic Upgrade of Soft Story, Type V wood frame Buildings. AB 0. 98. Post Earthquake Repair and Retrofit Requirements for Wood Frame Residential Buildings with Three or More Dwelling Units. AB 0. 99. Post Earthquake Repair and Retrofit Requirements for Concrete Buildings. AB 1. 00. Post Earthquake Repair and Retrofit Requirements for One and Two Family Units. AB 1. 02. RESERVEDAB 1. Voluntary Sprinkler Protection for Existing High Rise Buildings. AB 1. 06 Procedures for Implementation of SFEBC Chapter 4. D WordAB 1. 07 Application of Engineering Criteria in SFEBC Chapter 4. D WordAB 1. 08. Application of California Existing Building Code, Appendix Chapter A3. AB 1. 09. Application of Engineering Criteria in SFEBC Section 3. Word For Related Forms See Private School StructuresAB 1. Building Facade Inspection and Maintenance Word.