Huawei Terminal Length 0
Tutorial for Huawei Modules M2. MSupport. net. AT Command Tester is an free online software tool that can be used to test all features of Huawei modules. Huawei Terminal Length 0' title='Huawei Terminal Length 0' />Since the software tool is browser based, it can be used on all common PC based browsers Chrome, IE, Firefox, Safari and works on popular operating systems Windows, Linux, Mac. How to connect to Huawei module Typically module is hosted on some target platform host platform or hardware development kit HDK. Once the target platform is connected to the PC through a USB or serial cable and the drivers are installed, the module ports are avaialble on the PC as shown below. Depending on your module and the drivers, the port names might be listed differently. AT Command Tester is an free online software tool that can be used to test all features of Huawei modules. Since the software tool is browser based, it can be used on all common PC based browsers Chrome, IE, Firefox, Safari and works on popular operating systems Windows, Linux, Mac. On the AT Command Tester tool, Find Ports will list all the available serial ports. Connect to the port that maps to PC UI interface as shown above. Other option is to do Autoconnect AT Command tester will automatically find and connect to the connect to the appropriate port of the Huawei module. If the connection is successful, the model number and connection status will be shown as below,Diagnostics Commands. View and Download Huawei SUN200042KTL user manual online. SUN200042KTL Inverter pdf manual download. Huawei E3372 МТС 827F829F, МегаФон M1502, Билайн E3372E3370, TELE2 E3372h153 Обсуждение 4PDA. View and Download HUAWEI VP9050 user manual online. Executive Video Terminal V200R001. VP9050 Conference System pdf manual download. In the Diagnostics Command tab, information related to the device and the network can be easily queried from the device. To send Huawei module specifc diagnostics queries, select the Huawei drop down selection inside the Diagnostics tab. Get the module manufacturer. ATCGMIHuawei Technologies Co., Ltd. OKManufacturer Huawei Technologies Co., Ltd. Read the model number. ATCGMMMU6. 09. OKModel Number MU6. Get the revision number. ATCGMR1. 2. 1. 05. OKRevision 1. 2. Get the device capabilities. ATGCAPGCAP CGSM,DS,ESOKDevice supports following features GSM,Data Service,Device profile. AT V C 1 D 2 S 0 E 1 Q 0 V 1 X 1 S0 0 S3 1. S4 1. 0 S5 8 S7 0 S1. ICF 3,3 IFC 0,0. OKGet the battery status. ATCBCCBC 0,6. 1OKDevice is powered by battery. Device functionality. ATCFUNCFUN 1. OKDevice has Full functionality. Device status. ATCPASCPAS 4. OKCall in progress. Device clock. ATCCLKCCLK 1. OKCurrent time is1. Get the device serial number. ATCGSN3. 57. 78. OKCharacter set used by the module. Huawei-OLT-Configuration-backup-procedure.png' alt='Huawei Terminal Length 0' title='Huawei Terminal Length 0' />ATCSCSCSCS IRAOKCharacter set used by Terminal Equipment is IRAIndicators available from the module. The following indicators types are supported by the device,ATCINDCIND battchg,0 5,signal,0 5,service,0 1,call,0 1,roam,0 1,smsfull,0 1,GPRS coverage,0 1,callsetup,0 3OKThe indicator values are,ATCINDCIND 3,4,1,1,1,0,1,0. OKGet the GPRS class supported by the module. ATCGCLASSCGCLASS AOKCheck if any PDP context has been activated. ATCGACTCGACT 1,1CGACT 1. OKDevice is connected. Free Projection Edge Blending Software. Get the IP address of the connected PDP context. Huawei Terminal Length 0' title='Huawei Terminal Length 0' />ATCGPADDR 1CGPADDR 1,OKIP Address of the connected profile is Get the list of PDP contexts stored in the module. ATCGDCONTCGDCONT 1,IP,bluevia. CGDCONT 1. 5,IP,bluevia. OKFollowing connection profiles are available,CID 1. PDP Type IPAPN bluevia. PDP Address 0. Data Compression 0. Header Compression 0. CID 1. 5PDP Type IPAPN bluevia. PDP Address 0. Data Compression 0. Header Compression 0 Check if the device is attached to the network. ATCGATTCGATT 1. OKDevice is attached to the networkBearer configuration. ATCBSTCBST 0,0,1. OKSpeed autobauding. Bearer Service Data circuit asynchronous. Speedtouch 585 Firmware Download. Download there. Connection Element Non transparentRadio Link Protocol RLP paramerters. ATCRLPCRLP 6. CRLP 6. CRLP 2. 40,2. 40,5. OKRadio Link Protocol RLP Configuration paramaters IWF Window Dimension 6. MS Window Dimension 6. Acknowledge Timer 4. Retransmission Attempts 6. Protocol Version 0. ATFCLASS 0. OKThe device is configured for dataUSSD configuration. ATCUSDCUSD 0. OKService reporting. ATCRCR 0. OKService reporting control is disabledExtended error reporting. ATCEERCEER No cause information available. OKSignal strength. ATCSQCSQ 2. 3,9. OKSignal level is 6. Signal condition is excellent. The signal strength range is 5. Excellent to 1. Marginal. Current network operator. ATCOPSCOPS 0,0,AT T,2. OKDevice is currently on AT T network. Registration status. ATCREGCREG 2,5,7. CF4,2. 32. B5. 1B,2. OKDevice is registered and is roaming. Get the available networks. ATCOPSRSSI 1. Please wait as this could take sometime. RSSI 2. COPS 1,AT T,AT T,3. T Mobile,T Mobile,3. T Mobile,T Mobile,3. AT T,AT T,3. OKPreferred operator list. The preferred operator list ATCPOL OKSMS mode. ATCMGFCMGF 0. OKSMS message for is configured for PDU modeSMS service center address. ATCSCACSCA 3. OKSMS service center address is 3. SMS support. ATCSMSCSMS 0,1,1,1. OKService GSM 2. Compatible. Mobile Terminated SMS Supported. Mobile Originated SMS Supported. Broadcast SMS messages SupportedSIM card status. ATCPINCPIN READYOKSIM is ready. Sysinfo is a very useful AT command that provides info about the network. ATSYSINFOSYSINFO 2,3,1,5,1,4. OKServing Status Valid Services. Serving Domain PSCS Service Only. Roaming Status Roaming. Office 2007 Professional Trial Mirror Mirror. System Mode WCDMA Mode. SIM State Valid SIM card. System submode WCDMA Mode. ATSYSCFGSYSCFG 2,2,3. FFFFFFF,1,2. OKMode Automatic. Acquisition Order WCDMA GSMBand 3. FFFFFFFRoaming Supported. Serving Domain PSCS Service OnlyGet the system time. ATNWTIMENWTIME 1. OKDate 1. 40. Time 0. Daylight Saving 0. How the module is configured for wakeup ATWAKEUPCFGWAKEUPCFG 1,3,1. OKWakeup EnableDiable 1. Channel 3. Source 1. Get the IMEI number of the module. ATIMEISVIMEISV 3. OKIMEISV 3. GPIO configuration. ATIOCTRLIOCTRL 0. OKMapped as GPIO5,GPIO4,GPIO3,GPIO2,GPIO1. InputOutput 0. Value 1. Get the ICCID of the SIM card. ATICCIDICCID 8. OKICCID of the SIM card 8. USSD mode configuration. ATUSSDMODEUSSDMODE 1. OKConfigured for transparent USSD modeEcho cancellation for the audio paths. ATECHOECHO 4. OKEcho Cancel Speakerphone mode, loud echo, long delayPCM Audio configuration. ATCPCMCPCM 0,0,0,0,0. OKPCM Working Mode MASTERPRIMData Format Linear. Clock Signal 2. MHz. Frame Offset clearedSIM Tool kit mode. ATSTSFSTSF 1,2. OKSIM Tool Kit Mode STK Active. Raw. Mode Standard raw data modeRead the temperature. ATCHIPTEMPCHIPTEMP 6. OKThe temperature unit is 0. C. For example, if the returned value range is 2. C to 1. 00C. GSM PA temperature is not supported. WCDMA PA temperature is not supported. LTE PA temperature is not supported. SIM card temperature is not supported. Battery temperature is not supported. Crystal temperature 2. Check if temperature protection is enabled. ATTHERMFUNTHERMFUN 1. OKTemperature protection is enabledGet the NDIS connection status. ATNDISSTATQRYNDISSTATQRY 0,0,IPV4OKConnection Status Disconnected. USA Location information USA.